二维搜索
Sketch the part you are looking for or have a photo described in text form
Create image description with AI
Create image description with AI
Drop file here
支持的文件格式: .PNG, .JPG, .JPEG, .WEBP
1/5
1
1
2|0
3
4
4
0
0
0
0
0
0
0
0
0
0

FCH430.Y0.Y0.050E1.T1.H2.A.1.D1.G0.A

Expand Table
EN
1/5
Product type
PRODTYPE
Meter Size / Connection Size
DN
Meter Size / Connection Size
ZOLL [英寸]
Explosion Protection Certification
EXP
Connection Design / Connection Box Material / Cable Glands
BAU
Process Connection Type
PN
Material of Wetted Parts
MAT
Flow Calibration
DURCH
Density Calibration
DICHT
Connection Design / Transmitter Housing Type / Transmitter Housing Material / Cable Glands
BAUM
Outputs
AUS
Power Supply
EN
Certificates
ZERT
1
2
3
4
5
6
7
8
9
FCH430
DN 25 / DN 20
1 / 3/4
General Purpose
Integral, defined by Transmitter housing
Tri-Clamp acc. DIN 32676
Stainless steel polished 316L (1.4404 / 1.4435)
Flow forward +/- 0,40 % of flow rate, Gas 1 % of flow rate
Density 10 g/l
Integral / Dual compartment / Aluminium / 3 x M20 x 1.5
Current output 1 (active or passive), digitial output 1 & 2 (passive), HART
100 ... 230 V AC
-
FCH430
DN 25 / DN 25
1 / 1
General Purpose
Integral, defined by Transmitter housing
Tri-Clamp acc. DIN 32676
Stainless steel polished 316L (1.4404 / 1.4435)
Flow forward +/- 0,40 % of flow rate, Gas 1 % of flow rate
Density 10 g/l
Integral / Dual compartment / Aluminium / 3 x M20 x 1.5
Current output 1 (active or passive), digitial output 1 & 2 (passive), HART
100 ... 230 V AC
-
FCH430
DN 25 / DN 40
1 / 1-1/2
General Purpose
Integral, defined by Transmitter housing
Tri-Clamp acc. DIN 32676
Stainless steel polished 316L (1.4404 / 1.4435)
Flow forward +/- 0,40 % of flow rate, Gas 1 % of flow rate
Density 10 g/l
Integral / Dual compartment / Aluminium / 3 x M20 x 1.5
Current output 1 (active or passive), digitial output 1 & 2 (passive), HART
100 ... 230 V AC
-
FCH430
DN 50 / DN 40
2 / 1-1/2
General Purpose
Integral, defined by Transmitter housing
Tri-Clamp acc. DIN 32676
Stainless steel polished 316L (1.4404 / 1.4435)
Flow forward +/- 0,40 % of flow rate, Gas 1 % of flow rate
Density 10 g/l
Integral / Dual compartment / Aluminium / 3 x M20 x 1.5
Current output 1 (active or passive), digitial output 1 & 2 (passive), HART
100 ... 230 V AC
-
FCH430
DN 50 / DN 50
2 / 2
General Purpose
Integral, defined by Transmitter housing
Tri-Clamp acc. DIN 32676
Stainless steel polished 316L (1.4404 / 1.4435)
Flow forward +/- 0,40 % of flow rate, Gas 1 % of flow rate
Density 10 g/l
Integral / Dual compartment / Aluminium / 3 x M20 x 1.5
Current output 1 (active or passive), digitial output 1 & 2 (passive), HART
100 ... 230 V AC
-
FCH430
DN 50 / DN 65
2 / 2-1/2
General Purpose
Integral, defined by Transmitter housing
Tri-Clamp acc. DIN 32676
Stainless steel polished 316L (1.4404 / 1.4435)
Flow forward +/- 0,40 % of flow rate, Gas 1 % of flow rate
Density 10 g/l
Integral / Dual compartment / Aluminium / 3 x M20 x 1.5
Current output 1 (active or passive), digitial output 1 & 2 (passive), HART
100 ... 230 V AC
-
FCH430
DN 80 / DN 65
3 / 2-1/2
General Purpose
Integral, defined by Transmitter housing
Tri-Clamp acc. DIN 32676
Stainless steel polished 316L (1.4404 / 1.4435)
Flow forward +/- 0,40 % of flow rate, Gas 1 % of flow rate
Density 10 g/l
Integral / Dual compartment / Aluminium / 3 x M20 x 1.5
Current output 1 (active or passive), digitial output 1 & 2 (passive), HART
100 ... 230 V AC
-
FCH430
DN 80 / DN 80
3 / 3
General Purpose
Integral, defined by Transmitter housing
Tri-Clamp acc. DIN 32676
Stainless steel polished 316L (1.4404 / 1.4435)
Flow forward +/- 0,40 % of flow rate, Gas 1 % of flow rate
Density 10 g/l
Integral / Dual compartment / Aluminium / 3 x M20 x 1.5
Current output 1 (active or passive), digitial output 1 & 2 (passive), HART
100 ... 230 V AC
-
FCH430
DN 80 / DN 100
3 / 4
General Purpose
Integral, defined by Transmitter housing
Tri-Clamp acc. DIN 32676
Stainless steel polished 316L (1.4404 / 1.4435)
Flow forward +/- 0,40 % of flow rate, Gas 1 % of flow rate
Density 10 g/l
Integral / Dual compartment / Aluminium / 3 x M20 x 1.5
Current output 1 (active or passive), digitial output 1 & 2 (passive), HART
100 ... 230 V AC
-
显示压缩表示(9 konfigurierbares Produkt)
ShorttextCoriolis Mass Flowmeter
上次修改13.10.2025 12:00:50
单位

分类

CNS

CNSERPBASE Object Properties